![Dukane SVB031 User Manual Download Page 33](http://html.mh-extra.com/html/dukane/svb031/svb031_user-manual_2539133033.webp)
Spin Welder User’s Manual
Section 4 – Installation
Page 23
Page 22
Dukane Manual Part Number 403-547-03
Dukane Manual Part Number 403-547-03
The Base Interface to Press cable (Part No. 200–
1064) is a supplied part and is included with the
Spin Welder (see Table 2–1). The cable is connected
between J8 on the press and J35 on Base Interface
connector. This connection is illustrated in Figure
4–4. Both J8 and J35 are 14–contact female connec-
tors with 7 active contacts. The control cable carries
the operate and emergency stop signals from the
palm operate and abort switches on the base. If you
are using custom automation, you will have separate
operate and abort switches. These still connect to J8,
the press control input of the Spin Welder.
Top–Of–Stroke Cable
Directly above the press control input connector
is a 4–contact connector for the optional Top–Of–
Stroke cable (Dukane Part No. 438–528). This
connection utilizes the Top–Of–Stroke output from
the spin welder controls and is only required if you
are using the custom automation feature. This is a
normally–open contact which closes at the top of the
stroke. It is limited to a maximum of 24 Volts and 1
Amp. The cable pinout is shown in Figure 4–5.
AC Power
The AC power cord is permanently attached to
the main AC power switch box. This cable has a
4-prong twist–lock plug and requires 240 VAC
3–phase power rated at 20 Amps. This plug should
be connected to a NEMA L15–20R configuration
receptacle (see Figure 4–6). Inside the power
Figure 4–4
Base Interface to Press Connection
Panel
Connector
pinout is
the same
for both
J8–Press
and
J35–Base
Panel
Connector
View
J35
J8
Par
t No. 200
–1064
1
3
WHT
BLK
Figure 4–5
Top–Of–Stroke Cable