8.
Aligning the folding station plate as to the measuring line
Caution: Danger of injury !
Switch off the main switch.
Adjust the folding station plate of the loading station only with the
sewing unit switched off.
Standard checking
The distance between the middle of the needle and the inner side of
the folding station plate 1 must amount to 75 mm.
Between the bores of the cylinders 2 on the machine arm and the
inner side of the folding station plate 1 there should be a distance
of 60 mm ± 0.5.
–
Measure the distance between the folding station plate 1 and the
bores of the cylinders 2 when the loading station is swung in.
Correction
–
Push the covering cap to the back.
–
Loosen the bolt.
–
Turn the nut 5 and shift the bolt 6 in the guide.
–
Turn the nut 5 to the left: the bolt 6 moves backwards.
–
Turn the nut 5 to the right: the bolt 6 moves forwards.
–
The disc 4 must abut on profile 3.
–
Tighten the bolt 6.
–
Push the covering cap forward.
81
6
5
4
3
2
1