13.5.2
Aligning the flap clamps as to the pick-up folder
Standard checking
The flap clamp height above the fabric sliding sheet must amount to
14+3 mm
in swivelled-in position. The lateral distance of the flap
clamps to the pick-up folder has to be adjusted as close as possible
without touching it (Dimension
0.3+0.5 mm
).
(See sketch page 112)
Correction of the height (Dimension 14 + 3 mm)
Activate the output element
YC017
in the test program
“Selecting the
output elements”.
See also Programming Instructions, chapter 6.4.5.
The flap feeding devices swivel in.
–
Adjust the stop for the lowered position of the flap clamp lifting
device as described in chapter 13.5.3.
–
Loosen screws 1.
–
Turn the swivel arm 2.
–
Tighten the screws 1.
–
If required, readjust the shanks 3 and 4.
114
2
1
4
3
6
5