11.7
Safety switch for the folders
Caution: Danger of injury !
Switch off the main switch.
Check and adjust the switch lug 3 only with the sewing unit
switched off.
Standard checking
By means of the switches S22 and S23 it is checked whether the used
folder belongs to the selected sewing program.
In case of r/h single piping switch S22 must be actuated and in case of
l/h single piping switch 23 must be actuated.
The distance between the switches and the switch lug 3 should amount
to approx. 1 mm.
–
Check the distance between switch lug 3 and switch 2.
Correction
–
Slightly loosen screw 1.
–
Adjust the distance between switch lug 3 and the switches
S22/S23.
–
Tighten screw 1 again.
92
S23
3
S22
1