2.4.9
Aligning the needle bar linkage to the throat plate
Caution: Danger of injury !
Switch off the main switch.
Check and adjust the alignment of the needle bar linkage only with the
sewing unit switched off.
Standard checking
The needles should penetrate in the centre of the holes of throat
plate 3.
–
Insert new needles.
–
Slowly move the needle bars down by handwheel.
–
Check the position of the needles in the needle hole.
Correction
–
Loosen the screws 2.
–
Shift the needle bar linkage laterally in such a way that the needles
are in the centre of the needle holes.
–
Tighten the screws 2.
25
3
2
1