![Duerkopp Adler 745-34 Service Instructions Manual Download Page 98](http://html.mh-extra.com/html/duerkopp-adler/745-34/745-34_service-instructions-manual_2538350098.webp)
4
5
12.4 Adjusting the guide plates at the folder
Caution: Danger of injury !
Switch off the main switch.
Check and adjust the guide plates only with the main switch
switched off.
Standard checking
According to the material thickness and considering whether the flap is
to be positioned on the right or on the left the height of the guide plates
has to be adjusted in such a way that they can easily be lifted by the
workpiece. The guide plates have to be close beside the needles, but
must not touch the needles or the needle block.
–
Check the position of the guide plates.
–
Check the spring pressure (important with regard to the folding and
seam quality).
–
Check the free movement of the needles 2 and needle block 3 with
regard to the guide plates.
Correction
Adjusting the guide plate height
–
Loosen nut 5.
–
Adjust the guide plate height with core pin in nut 5.
–
Tighten nut 5.
Adjusting the spring pressure
–
Loosen nut 4.
–
Adjust the spring pressure with core pin in nut 4.
–
Tighten nut 4.
Adjusting the guide plates aside the needles
–
Carefully align the guide plates 1 with a pair of pliers.
96
3
2
1