2.11
Synchronizer
Caution: Danger of injury!
Switch off the main switch.
Adjust the synchronizer only with the sewing unit switched off.
Standard checking
After positioning the thread lever should be at the top dead centre.
The distance between the synchronizer 2 and the cam segment 5
should amount to approx. 0.5 to 1.0 mm.
Correction
–
Loosen counternut 1.
–
Adjust the distance between synchronizer 2 and the maximum
outer diameter of cam segment 5.
Dimension = 0.5 to 1.0 mm.
–
Tighten counternut 1.
–
Turn the sewing machine in position “Thread lever at top dead
centre".
–
Loosen screws 4.
–
Turn the cam segment 5 in such a way that the switching cam 3 is
positioned exactly on the synchronizer 2.
–
Tighten screws 4.
–
Check the positioning after cutting.
52
5 4
3
2
1