![Duerkopp Adler 745-34 Service Instructions Manual Download Page 156](http://html.mh-extra.com/html/duerkopp-adler/745-34/745-34_service-instructions-manual_2538350156.webp)
18.
Maintenance
Caution: Danger of injury !
Switch off the main switch.
The maintenance of the sewing unit must only be carried out when the
machine is switched off.
The daily or weekly maintenance work (cleaning and oiling) to be done
by the operators of the sewing unit is described in Part 1: Operating
Instructions. It is only listed in the following table to complete the
picture.
Work to be done
Operating hours
8
40
160
500
Machine head
Remove bits of fluff, sewing dust and thread tails from the area
around the hook and the throat plate
X
Supply the oil feed holes with oil (see Operating Instructions, chapter 3.2)
X
Check the oil level in the oil reservoirs
X
Check the oil flow at the inspection glass
X
Check the hook lubrication
X
Clean the lenses of the bobbin thread monitor
X
Clean the reflecting foils
X
Drive unit and transport carriage
Check state and tension of the V-belts and toothed belts
X
Clean the filters at the front and at the back of the step motor amplifier
X
Clean the motor fan grill
X
Oil the feeding device B, eccentric axle 3 (ill. page 103).
X
Pneumatic system
Check the water level in the pressure regulator
X
Clean the filter insert of the maintenance unit
X
Carry out leak test
X
Additional equipment
Clean the inlet air and waste air filter of the suction unit (blow out)
X
154