![Duerkopp Adler 745-34 Service Instructions Manual Download Page 18](http://html.mh-extra.com/html/duerkopp-adler/745-34/745-34_service-instructions-manual_2538350018.webp)
–
Loosen the counternut 12.
–
Loosen the adjusting screw 13 a bit.
ATTENTION !
Do not
loosen both adjusting screws 13.
With the two adjusting screws 13 the correct height of the linkage
frame has been set by the manufacturer.
ATTENTION !
Avoid damage to the oil wick when taking off the needle bar.
Note the position of the oil wick for the subsequent assembly.
–
Carefully remove the support plate 9 with the needle bar linkage 10
from the stop pin 11.
This is facilitated by slight turning motions.
16
10
9
13
12
11