Frost protection
The unit features frost protection as standard in order to protect it at very low outdoor temperatures and enable it to operate
correctly� The supply flow rate is slowed down gradually such that more warm air passes across the heat exchanger� This prevents
the heat exchanger from freezing up� If the imbalance is insufficient to prevent it from freezing up, then the unit will be temporarily
switched off�
Constant Flow
The unit features constant-flow control� This ensures that the air flow rate remains constant between the supply and extract side
should the filters become blocked�