12
ENGLISH
L2000782 Installation guide for DucoBox Energy Comfort (Revision B.1 | 25.03.2020)
Slide the cardboard packaging off
the unit� If the unit is wall mounted,
the cardboard can be removed from
under the unit once it has been
hung�
1
200 kg/m²
900 mm min�
with standard
condensate drain
700 mm min�
with flat siphon
(0000-4376)
The unit must be mounted ver-
tically against a solid wall with a
minimum mass of 200 kg/m² for
a vibration-free mounting� Plas-
ter blocks or metal struts are not
adequate! The type of condensate
drainage and air ducting chosen
will determine the exact height�
2
Fasten the hanger bracket ho-
rizontally to the wall, ensure it
is hanging level when doing so�
Ensure at the same time that the
screws* and plugs* are suitable for
the substrate and the weight of the
unit (21 kg)�
* screws and plugs not included in the supply
3
Hook the unit onto the drop hanger�
Use the garb handles in the card-
board at the bottom of the unit�
4
Remove the cardboard from the
bottom of the unit�
5
Check whether the unit is spi-
rit-level against the wall� This will
ensure that condensate drains off
properly�
6
06.B
Fastening the DucoBox Energy Comfort
Maintain at least 60 to 100 cm clear at the front of the DucoBox Energy Comfort to enable maintenance to be
carried out on the unit�
Wall mounting
The DucoBox Energy Comfort can be fastened to a wall or if there is no wall available that will do, the DucoBox Energy Comfort can
be installed on an optional mounting plinth�