13
ENGLISH
L2000782 Installation guide for DucoBox Energy Comfort (Revision B.1 | 25.03.2020)
Floor mounting
Slide the cardboard packaging off
the unit�
1
Fit the optional mounting plinth
in accordance with the manual
supplied with it and ensure that it is
positioned on a solid, flat surface�
2
Place the DucoBox Energy Comfort
on the mounting plinth and check
again to ensure it is level� This will
ensure that condensate drains off
properly�
3
06.C
Placing the Humidity Box Sensor (optional)
The optional, separately available Humidity Box Sensor (0000-4545) is placed in the discharge duct of the DucoBox Energy Comfort
and centrally measures the humidity of the air discharged from the house� A DucoBox Energy Comfort contains a maximum of one
box sensor�
Connecting the Humidity Box
Sensor to the DucoBox Energy
Comfort
1
Make sure the DucoBox Energy Com-
fort is not under current�
2
Push the Humidity Box Sensor onto
the ETA duct of the DucoBox Energy�
Place an air duct between the Duco-
Box Energy Comfort and the Humidity
Box Sensor�
Attention: the position of the ETA
duct depends on the chosen set-
tings for starting the apparatus (see
3
Connect the cable of the Humidity Box
Sensor to the printed circuit board
(see 'Connections' on page 8) � The
DucoBox Energy Comfort will auto-
matically recognise the Humidity Box
Sensor when the device starts�
ETA!