ENGLISH
L2000782 Installation guide for DucoBox Energy Comfort (Revision B.1 | 25.03.2020)
05
Wiring
The DucoBox Energy Comfort is able to communicate with slave components via a wireless (RF) or wired link� Both types of com-
munication can be combined in one system�
Communication with non-Duco components is possible via the Switch Sensor or one of the connections on the optional Communi-
05.A
Cabling diagram
Loosen the screws�
1
Slide the cap forwards�
2
Cut one or more or the specified
pieces away from the housing to
connect cables�
3
05.B
Connecting cables to the PCB
RF
24 VDC
24 VDC
A B GND
B
A
GND
POWER
SUPPLY
User controller
RF
230 VAC
User controller
230 VAC
230 VAC
Max. of 50 components of which no more than 25 RF
RF obstacle-free zone (at least 30 cm)
Colours
230 VAC
brown + blue
24 VDC
brown + white
A
yellow
B
green
GND
grey