SYSTEM STATUS AND DATA MESSAGES
The table below is a summary of status and data messages produced by the LGR 2800i. The left column shows the
messages that appear on the control panel display. The center column shows the messages that are relayed to the
HygroTrac remote monitoring system and displayed on the HygroTrac website. The HygroTrac website will also display
one of three status messages for each 2800i detected by a HygroTrac gateway: S for standby (the unit is disconnected
from AC power but the wireless transmitter is working properly), A for active (the unit is sending normal data and status
messages), or I for inactive (the unit is sending no messages).
C O N T R O L P A N E L
M E S S A G E
H Y G R O T R A C
W E B S I T E M E S S A G E
E X P L A N A T I O N
SYST
EM
ST
A
T
U
S
UNIT ON 00 HRS
Dehumidifier On
Normal operation.
UNIT ON 00 HRS
DEFROST CYCLE
In Defrost Mode
Normal operation. Unit is in defrost mode. No
action required.
OFF
Dehumidifier Off AC power
present.
Unit is turned off. AC power present.
UNIT ON 00 HRS
POWER FAILURE>
Dehumidifier Restarted after
Power Failure
Unit experienced a power failure but has
successfully restarted.
HUMIDISTAT
INLET XXX°F
Humidistat Controlled
Humidistat mode is active and dehumidifier
energized.
HI TEMP CYCLE
REMAINING 00 MIN
In High Temp mode
Normal operation. Unit has detected higher
ambient temperatures and switched modes to
operate more efficiently. No action required.
[display is blank]
Stand-by Mode
No AC power. Wireless transmitter functioning
normally. No action required.
ERROR MESSAGES
The table below shows error message that the system may detect. If the display shows an “ER” message, first unplug the
unit and then plug it back in. This may re-set the electronics, and if so, no further action is required. If the error message
reappears, try the solution shown under “Explanation.” If this still does not fix the problem, contact your local authorized
service center or the Dri-Eaz Service Department at 800-932-3030.
SYST
EM
ER
R
O
R
ER1 CONTACT SERVICE
CENTER
Failure: Contact Service
Center
Check AC power for inadequate voltage. The
electronic control panel may require replacement.
Contact service.
ER2 CONTACT SERVICE
CENTER
Failure: Contact Service
Center
The electronic control panel may require
replacement. Contact service.
ER3 CONTACT SERVICE
CENTER
Failure: Contact Service
Center
Check defrost sensor for proper connection.
Check sensor cable for damage. Sensor assem-
bly may need replacement. Contact service.
ER4
√ DEFROST SENSOR
CONNECT
– or –
ER4
√ OUTLET SENSOR
CONNECT
Check Sensor Connections
Check defrost sensor for proper connection.
Check sensor cable for damage. Sensor assem-
bly may need replacement. Contact service.
C O N T R O L P A N E L
M E S S A G E
H Y G R O T R A C
W E B S I T E M E S S A G E