07-01674D 2009-08
5
Dri-Eaz Products, Inc.
JOB HOURS
RESET? >
Press
to reset hours to zero. NOTE: When in
Humidistat mode, the unit will display HUMIDISTAT on
the top line during normal operation rather than JOB
HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be
modified.
INLET
OUTLET
00° 00%
00° 00%
Shows current temperature and RH of inlet and outlet.
The HygroTrac system uses these values to calculate
grain depression.
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
to toggle between ON and OFF.
NOTE: When in Humidistat mode, the unit will display
HUMIDISTAT on the top line during normal operation
rather than JOB HOURS.
HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode (see
above). Press
to change RH value at 5% increments.
Settings cycle upward through 90%RH and start again at
30%RH.
TEMPERATURE UNIT
F° >
Shows current temperature scale. Press
to select
Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
to
select Spanish, German, French or English.
COIL TEMP
00°F
Displays the cold (evaporator) coil temperature.
SENSOR ID >
00000000
Shows built-in wireless transmitter number. The
HygroTrac system uses this to uniquely identify your
2800i unit. NOTE: For convenience, this same number is
shown on the barcode label affixed to the control panel.
Press
to cycle through the following values:
SENSOR
TYPE
,
SENSOR REVISION
, and
SENSOR CONF REV
.
A Dri-Eaz service technician may ask you for these
values when diagnosing a problem.
COMPRSSR CURRENT
0.0 A
Shows compressor current draw in amps.
Error messages
If the LGR 2800i onboard diagnostics discover a
problem, the unit will display an error message. If the
unit is used with the HygroTrac system, it will also
transmit most error messages to the user’s HygroTrac
website. See “System Status and Data Messages” and
“Error Messages,” p. 8, for a summary of messages.
At the end of the job
As with all dehumidifiers, once the drying job is
completed, it is important to make sure the unit is
completely purged of water before moving it. To ensure
that all water has drained into the pump, follow these
steps:
1. Turn the unit off and allow the plugged in dehumidifier
to rest for 10 minutes.
2. Press the
PURGE
button and while the purge pump is
operating, tip the unit back approximately 45° and hold
the unit in place until the purge cycle is complete. This
allows any water remaining on the coils to drain down
into the pump.
3. Return the unit to the upright position and press
PURGE
one more time to empty the pump. Once the
purge cycle is complete, unplug the unit and remove it
promptly from the job.
Before transporting, be sure to remove the external drain
hose, drain it carefully, and return it to the pocket
provided on the back of the unit.
MAINTENANCE
WARNING! ELECTRIC SHOCK HAZARD.
Unplug
the LGR 2800i dehumidifier before performing any
maintenance.
Before each use
Inspect the electrical cord for damage.
Look for
fraying, cuts, etc. Do not use the unit if you find any