44/57
More on Installation
Eco Mode
Eco Mode automatically optimises the stop time
of a heating phase, to maximise the efficiency
of your heating system, each time the set
temperature changes from a higher temperature
(e.g. 21C) to a lower one (e.g. 16C).
A
Eco Mode deactivated
Wiser switches the set-point temperature at 10
pm according to the schedule. Depending on
the weather and how well-insulated the home
is, the room temperature drops proportionally
starting at 10 pm.
B
Eco Mode activated
When Eco Mode is activated, Wiser establishes
how well your home retains heat in relation to
the current and predicted outdoor temperatures.
Based on this, the system switches to the next
scheduled set-point temperature before 10 pm
without any noticeable loss of comfort.
The period between the time that Eco Mode
switches the set-point and 10 pm represents
the eco period, and savings occur as a result of
the boiler not being switched ON.
Note:
Eco Mode is a system feature that is
either activated or deactivated for all rooms.
°C
t
°C
t
6
6
A
B
°C
t
°C
t
10
10
A
B
The boiler stops firing before 10PM
Eco period
The boiler keeps cycling until 10PM
Set temperature
Room temperature