476
Issue date: 17 November 2006
13 of 80
temperature to stabilise and
then charge.
Solid amber
Was fully charged but now battery
drained.
Check BA set is shut down
correctly and the air is
purged. Remove charger and
refit. If the problem persists
contact OSG.
Single flash amber
Charging (fast) low capacity.
Leave on charge.
Double flash amber
Fault, Battery low capacity or battery
temp may be too high or too low.
Remove from charge. Leave
approximately 30 minutes for
temperature to stabilise and
then charge.
7
FPS 7000 dual purpose face mask
Face mask identifying features
LFB image 201850
Head harness
Sliding buckle
Mask body
Visor
Inner mask
ESA
connection
Exhalation
valve cover