476
Issue date: 17 November 2006
20 of 80
•
Button activated manual distress signal unit (DSU).
•
A ‘backlight’ – illuminating the display.
Pressure transmitter module
11.5
Pressure connection
– pressure sensor (see paragraph 9.14) for connection to the high
pressure outlet port of the first stage pressure reducer via a high pressure connection hose (see
image 245556).
11.6
Outlet connection
– hose/cable link to the Bodyguard unit.
Rechargeable battery pack
11.7
The rechargeable battery pack cannot be changed at station. If
a ‘reduced battery’ icon is displayed investigate why i.e. is the
charging lead connected or is the charging point defective on
the appliance, try changing the set position to see if the
charging icon is displayed on the Bodyguard display:
•
Main power – 6.5 volts.
•
The Bodyguard is powered by a 6.5 volt rechargeable battery pack.
•
Actual operating time of the battery pack is dependent on how long the system has been
operating, frequency of alarms, ambient temperature and frequency of use of the backlight.
•
With the system switched ‘off’ a small amount of power is still consumed.
•
Note: All electronic devices may suffer a temporary loss of function if subjected to high levels
of radio frequency (RF) radiation.
•
The Bodyguard will continue to operate with no loss of performance or loss of function, once
the RF radiation has been removed.
12
Bodyguard in use functions
Display – operating mode
12.1
The Bodyguard user interface displays cylinder pressure and TTW. The upper
numeric value and radial segments indicate cylinder pressure (see image right).
12.2
The lower numeric value indicates the TTW and the activation of the visual
LEDs.
12.3
The display alternates between TTW and telemetry signal status at
approximately five second intervals (see image right ‘telemetry signal radio’
icon ticked for ‘in’ telemetry signal).
12.4
The green LED on the front of the display unit flashes at one second intervals when in
‘operational mode’.
12.5
The two blue LEDs on the front of the display unit flash at one second intervals
when ‘in’ telemetry signal.
12.6
The EDBA set Bodyguard also features a first alert, this is indicated at
192
bar
by two short ‘bleeps’ and is an indication that
50%
of the available working duration of the EDBA
set has been reached.
Backlight
12.7
To illuminate the display – briefly press the
left
button. The display will illuminate for ten
seconds.
LFB image 245556