![Dräger FTS 8000 Operating Manual Download Page 68](http://html1.mh-extra.com/html/drager/fts-8000/fts-8000_operating-manual_2526524068.webp)
Operation
Edition 03 / 69 06 898
64
FTS 8000
5.8
Fireplaces
5.8.1
Flash over (gas-fired)
1. Open and lock the smoke barrier completely.
2. Fully open and secure the container 2 portal door located on the right when looking at
the fireplace.
3. Start the ignition flame. Once the pilot flame has been successfully ignited, the
support file starts automatically. Pilot flame and support fire are switched off after 15
minutes if the flash over (gas-fired) is not ignited.
4. To start the flash over (gas-fired), press and hold the switch on the remote control.
Releasing the switch disconnects the flame.
5. Maximum possible burning duration is 15 seconds, and this is followed by a cooling
time of 10 seconds. It is only possible to re-start the flash over (gas-fired) after the
required cooling time.
6. The intensity of the flame can be set using the rotary switch on the remote control.
The three lock positions are set via the system control.
5.8.2
Fire pan
1. Start the ignition flame. The pilot flame is switched off after 15 minutes if the main
flame is not ignited.
2. To start the fireplace, press the corresponding switch on the remote control (+).
3. The flame level (1 to 3) is increased by pressing the (+) button and reduced by
pressing the (-) button.