Assembly and installation
Edition 03 / 69 06 898
33
FTS 8000
18. Close the ceiling transition between containers 2 and 3 with cover plates. To do this,
slightly unfasten the nuts in the cover plate slots. Push the cover plate against the
ceiling of container 2. Re-tighten the nuts by hand.
19. Remove and safely store the straps on the side doors of the container.
3.5.2
Connect the power supply
Fig. 35 Connection on main earthing bolts.
!
WARNING
Electrical voltage
When setting up equipotential bonding, there is a risk of fatal electric shock.
Power may only be fed in after the ground cables have been connected.
!
WARNING
Danger of death and risk of equipment damage as a result of lack of equipotential bonding
Ensure sufficient grounding of the training gallery. If sufficient grounding is not possible,
the supplied grounding pin must be inserted and connected to the training gallery. If in
doubt, have a specialist company check the grounding. The grounding or the grounding
pin for equipotential bonding must be mounted and fixed before connecting any lines.
Fig. 34 Ceiling transition between C2 and C3