Overview and description of functions
Edition 03 / 69 06 898
11
FTS 8000
The system consists of three fire simulation containers, each with one fireplace. On
container 1, the technical room is connected to the switch cabinet. Containers 1 and 2 are
aligned perpendicularly and connected using bridge fittings. Container 3 is aligned at a
90 °C angle to container 2 and connected with bridge fittings. Container 3 is connected by
a door to containers 2 and 1, and containers 1 and 2 project into one another.
2.3
Safety and monitoring equipment
The fire simulation system is equipped with the following technical safety devices:
•
Emergency stop button
•
Gas sensors
•
Temperature sensors
•
X-zones
•
Wireless connection of the remote control to the receiver (not illustrated)
!
WARNING
Danger of death in the event of changes to safety and monitoring devices
Do not remove, modify or block safety devices such as safety and monitoring devices. Do
not operate the system if any one of the safety and monitoring devices is not fully
functional.
!
WARNING
Risk of injury and of equipment damage due to faulty detection
The gas sensors require a warm-up phase of 15 minutes to be fully operational. No
correct measured values can be displayed during this time. The gas sensors are not yet
fully functional.
i
i
NOTICE
The gas sensors could display different values due to external influences. The deviation
could be up to 3%.
An emergency stop is ensured at all times when a gas concentration of 25 % of the lower
explosive limit is reached.
Fig. 2 Emergency stop
button
Fig. 3 Gas sensor
Fig. 4 Temperature
sensor
Fig. 5 X-zone