![Dräger FTS 8000 Operating Manual Download Page 30](http://html1.mh-extra.com/html/drager/fts-8000/fts-8000_operating-manual_2526524030.webp)
Assembly and installation
Edition 03 / 69 06 898
26
FTS 8000
3
Assembly and installation
3.1
Target groups
The assembly and installation is only permitted to be performed by the following target
groups:
•
Technical personnel
3.2
Safety instructions
!
DANGER
Danger of death and property damage due to unsuitable lifting gear
Only authorized and trained specialist personnel may assemble and install the fire
simulation system.
!
DANGER
Danger of death due to lack of personal protective equipment (PPE)
The personal protective equipment is to be worn during all work on the fire simulation
system.
In line with regulations, these include helmet, safety shoes, gloves and protective clothing.
!
WARNING
Risk of injury and of equipment damage due to lack of stability of the fire simulation
system
The surface must be designed for the exercise and the weight of the fire simulation
system.
!
WARNING
Risk of falling and crushing
When setting up the fire simulation system, ensure sufficient fall protection according to
local regulations. There is a risk of crushing when folding the different components in or
out.
!
WARNING
Danger of death and risk of equipment damage as a result of lack of equipotential bonding
Ensure sufficient grounding of the training gallery. If sufficient grounding is not possible,
the supplied grounding pin must be inserted and connected to the training gallery. If in
doubt, have a specialist company check the grounding.
The grounding or the grounding pin for equipotential bonding must be mounted and fixed
before connecting any lines.
!
WARNING
Danger of death due to gas leak
Following setup at another installation site, the entire pipe system must be tested for leaks
using a mobile gas detector.