background image

14

Approval Label/Etiquette d'homologation/Etiqueta de homologación 

01921592.eps

Draeger Safety AG & Co KGaA

D - 23560 Luebeck

Phone : 011 49 451 882-0

US Phone: 1-800-922-5518

TC-

Protection

 1

Canister

Cautions and Limitations 

2 / 3

CDR 4500

EPDM-PC-C-RA-K/sw

Plastic black

CDR 4500 

EPDM-PC/C-RA-blank

steel blank

CDR 4500 

EPDM-PC/C-RA-sw

steel black

CDR 4500 

EPDM-PC/C-RA-

S

-sw

steel black

CDR 4500 

EPDM-PC/C-RA-

S

-blank

steel blank

CDR 4500

EPDM-PC/C-RA-

L

-sw

steel black

CDR 4500

EPDM-PC/C-RA-

L

-blank

steel blank

CBRN Cap 1

Spectacle kit

Spectacle kit

Spectacle kit

Pnova

Trispec

R 55 440

R 55 705

R 55 710

R 55 575

R 55 715

R 55 580

R 55 720

67 38 146

R 51 548

 40 56 821

40 57 622

14G-0286

CBRN Cap 1

X

X

X

X

X

X

X

X

XX

X

 A J L M O R T V W X Y Z CC HH QQ UU 

1 Protection 

CBRN Cap 1 - Capacity meets

minimum 15 min test time

2 Cautions and Limitations

A - Not for use in atmospheres containing less than 19.5% oxygen.

J - Failure to 

p

ro

p

erl

y

 use and maintain this 

p

roduct could result in in

jur

y

 or death.

L - Follow the manufacturer's User's Instructions for changing cartridges and/or filters.

M - All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA, and other applicable 

regulations.

O - Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.

3 CBRN Cautions and Limitations

R - Some CBRN agents may not present immediate effects from exposure, but can result in delayed impairment, illness, or death.

T - Direct contact with CBRN agents requires proper handling of the respirator after each use and between multiple entries duri

ng the same use. 

     Decontamination and disposal procedures must be followed. If contaminated with liquid chemical warfare agents, dispose of 

the respirator after decontamination.

V  - Not for use in atmospheres immediately dangerous to life and health or where hazards have not been fully characterized.

W - Use replacement parts in the configuration as specified by the applicable regulations and guidance.

X  - Consult manufacturer’s User’s Instructions for information on the use, storage, and maintenance of these respirators at va

rious temperatures.

Y  - This respirator provides respiratory protection against inhalation of radiological and nuclear dust particles. Procedures 

for monitoring radiation 

      exposure and full radiation protection must be followed.

Z   -  If during use an unexpected hazard is encountered such as a secondary CBRN device, pockets of entrapped hazard or any un

foreseen hazard, immediately leave the area for clean air.

CC -  For entry, do not exceed maximum use concentrations established by regulatory standards.

HH - When used at defined occupational exposure limits, the rated service time cannot be exceeded. Follow established canister c

hange schedules or 

       observes End of Service Life Indicators to ensure that canisters are replaced before breakthrough occurs.

QQ - Use in conjunction with personal protective ensembles that provide appropriate levels of protection against dermal hazard.

 Failure to do so may result 

        in personal injury even when the respirator is properly fitted, used, and maintained.

UU - The respirator should not be used beyond eight (8) hours after initial exposure to chemical warfare agents to avoid possib

ility of agent permeation. 

        If liquid exposure is encountered, the respirator should not be used for more than two (2) hours.

THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS

CDR 4500 AIR-PURIFYING GAS MASK RESPIRATOR

Alternate Facepiece

Respirator Components

Accessories

Visit: www.thesafetyequipmentstore.com Or Email: [email protected] for Sales & Service.

Summary of Contents for CDR 4500

Page 1: ...500 001_CDR4500 tif NIOSH enUS Instructions for Use 2 fr Notice d utilisation 6 es Instrucciones de uso 10 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales S...

Page 2: ...rking is externally legible and positioned on the mask DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially ha...

Page 3: ...ion Standard 29 CFR 1910 134 Failure to do so can result in serious personal injury or death 00821592_1 eps Fig 2 00221592_1 eps 1 Fig 3 00321592_1 eps 2 1 3 Fig 4 01321592_1 eps Fig 5 Positive Fit Ch...

Page 4: ...isinfection times can damage the mask 00421592_1 eps Fig 10 Maintenance Regular service maintenance and pre use checkouts of your CDR 4500 is of the utmost importance to ensure safe use of the device...

Page 5: ...for un used stored mask in original packaging otherwise every 6 months Visually inspect correct function and leak check X X1 Replace exhalation valve disc X Replace speech diaphragm X Visual check by...

Page 6: ...pas respect es il y a un possible risque de mort ou de blessure grave en raison d un danger potentiel ATTENTION Si les mesures de prudence ad quates ne sont pas respect es il y a un possible risque de...

Page 7: ...point peut entra ner des blessures graves ou mortelles 00821592_1 eps Fig 2 00221592_1 eps 1 Fig 3 00321592_1 eps 2 1 3 Fig 4 01321592_1 eps Fig 5 Contr le d ajustage positif Placez la paume de votre...

Page 8: ...92_1 eps Fig 10 Entretien Il est extr mement important d effectuer une r paration et un entretien r guliers de l quipement ainsi que de mener les contr les pr utilisation de votre CDR 4500 a n d assur...

Page 9: ...asques non utilis s et stock s dans leur emballage d origine sinon tous les 6 mois Contr le visuel contr le du bon fonctionnement et recherche de fuites X X1 Remplacement du disque de la soupape expir...

Page 10: ...correspondientes ADVERTENCIA Existe el peligro potencial de muerte o de sufrir lesiones graves si es que no se toman las medidas de precauci n correspondientes ATENCI N Existe el peligro potencial de...

Page 11: ...i n de la respiraci n En caso que no se realice esto se pueden sufrir lesiones o accidentes mortales 00821592_1 eps Fig 2 00221592_1 eps 1 Fig 3 00321592_1 eps 2 1 3 Fig 4 01321592_1 eps Fig 5 Prueba...

Page 12: ...muy alta y una exposici n prolongada a los desinfectantes puede da ar la m scara 00421592_1 eps Fig 10 Mantenimiento La realizaci n de trabajos de mantenimiento y conservaci n regular as como pruebas...

Page 13: ...co Dr ger o certi cado con el nivel II por Dr ger 00721592_1 eps Fig 13 Control visual de v lvula de exhalaci n Sacar la tapa de protecci n del conector de la m scara y revisar cuidadosamente el disco...

Page 14: ...quid chemical warfare agents dispose of the respirator after decontamination V Not for use in atmospheres immediately dangerous to life and health or where hazards have not been fully characterized W...

Page 15: ...15 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Page 16: ...August 2006 Subject to alteration Dr ger Safety AG Co KGaA Revalstrasse 1 D 23560 Luebeck Germany Tel 49 451 8 82 0 Fax 49 451 8 82 20 80 www draeger com Distributed By The Safety Equipment Store www...

Reviews: