Duration of Use

The operating period depends on various factors, including the type and 
concentration of pollutant and the type of filter (see also the Instructions for 
Use of canisters).
The canisters are for single use only!

After Use

Unscrew the respiratory canister.

Remove the mask as follows:
Insert index finger behind the tabs on the 
neck straps.
Press the clamping buckles forwards with 
thumbs while pulling the full face mask off 
your face and back over your head.

Disposal

Used respiratory canisters must be treated as special waste and must be 
disposed in accordance with the applicable waste disposal regulations.

Cleaning, Disinfection and Drying

Only use approved cleaning and disinfecting agents!

Cleaning

The mask must be cleaned after every use so that it is clean before it is 
used by a different individual or, if individually assigned, as often as 
necessary to keep in a sanitary condition. 
Respirators that are issued to more than one employee must be cleaned 
before being worn by different individuals.

Clean the mask with a cloth and lukewarm water mixed with an all-
purpose detergent, e.g. Airkem 33. 

Rinse thoroughly under running water.

Disinfection and Decontamination

The mask must be disinfected and decontaminated after every use to keep 
it in a sanitary condition. It is fully in the user’s responsibility to make sure 
that the mask is totally free of contaminants after this treatment.

Immerse the mask in a disinfectant bath. 

Rinse thoroughly under running water.

For exposure to CBRN agents Dräger does not provide recommendations 
for decontamination. Never use a mask again, which is not properly 
disinfected and decontaminated. In case of doubts dispose of the mask in 
accordance with the local regulations and use a new mask!

Drying

Dry the mask in a drying cabinet or in a clean area. Maximum temperature 
140 

o

F (60 

o

C). Do not expose the mask to direct sunlight.

Storage

Loosen the straps as far as possible. 

Wipe lens with anti-static cloth. 

Pack the mask in its bag or mask box and store it in a dry, dust-free place 
where it is not deformed.

Keep out of direct sunlight and heat.

Storage temperature rated range: 5 

o

F to 77 

o

F  (-15 

o

C to +25 

o

C). 

Maximum storage temperature temporary: 140 

o

F (+60 

o

C).

DANGER!
Doff full face mask only outside of hazardous areas, 
never inside! Make sure that the wearer is not harmed 
by the surface-contaminated mask. Avoid direct contact 
to skin and inhalation of hazardous substances.

NOTE
Do not use any organic solvents such as acetone, 
alcohol etc. to clean the rubber parts.

DANGER!
Use only approved disinfectants, e.g. Airkem 33. 
Excessive disinfectant concentration and too long 
disinfection times can damage the mask.

00421592_1.eps

Fig. 10

Maintenance

Regular service, maintenance, and pre-use checkouts of your CDR 4500 is 
of the utmost importance to ensure safe use of the device. Thus it is 
absolutely mandatory that you strictly follow the “Maintenance Intervals” on 
page 5, below.
Repair of the CDR 4500 may only be carried out by trained and qualified 
service personnel. 
We recommend you enter into a service contract with Dräger Safety; that 
all repairs on your CDR 4500 be conducted by Dräger Safety; and that 
only original Dräger parts be used for maintenance and repairs.

Replacing the Lens

Loosen the two clamping screws. 

Pry the lens frame apart with a screwdriver at the connecting points, then 
pull off the top and bottom parts. 

Remove the gusset if necessary. 

Detach the old lens from its rubber frame.

Insert the new lens first in the upper and then in the lower part of the 
rubber frame. The center marks on the lens should be aligned with the 
seam on the facepiece. 

Pull the rubber frame over the edge of the lens on the right and left.

Moisten the outside of the rubber frame and the inside of the lens with 
soap solution. 

Fit the upper, then the lower lens frame. 

Fit the gusset if necessary. 

Tighten the clamping screws.

Leak test the mask (see “Testing / Visual Inspection” on page 5).

Replacing the Facepiece Connector

Draw the nose cup out of the groove in the 
screw ring. 

Pry open the connector clamp using a 
screw-driver. 

Remove connector clamp, sliding ring and 
gusset. 

Draw the facepiece connector out of the 
mask body.

Insert speech diaphragm, exhalation valve and inhalation valve into the 
new mask connector, and fit the connector so that the center marks of the 
mask connector and mask body match. 

Slide the gusset between connector clamp 
and sliding ring; attach it to the lower lens 
frame and align it.

Compress the nose on the connector clamp 
with pliers (R 53 239) until the facepiece 
connector is securely located in the mask 
body. 

Fit the nose cup.

Leak test the mask (see “Testing / Visual Inspection” on page 5).

Replacing the Valve Discs on the Nose Cup Valves

Pull out the old valve disc towards the inside. 

Insert the stud of the new disc into the hole from inside, and pull it 
towards the lens until the undercut of the stud is visible. The valve discs 
should make even contact with the inside surface.

WARNING!
The CDR 4500 must be regularly inspected and 
serviced by qualified service personnel, and the 
“Maintenance Intervals” on page 5 must be strictly 
followed.
Failure to follow this warning could lead to death or 
serious injury.

NOTE
Only use original Dräger parts. 
Leak tests must be repeated after any maintenance 
work and/or after replacing components.

00521592_1.eps

Fig. 11

00621592_1.eps

Fig. 12

Visit: www.thesafetyequipmentstore.com Or Email: [email protected] for Sales & Service.

Summary of Contents for CDR 4500

Page 1: ...500 001_CDR4500 tif NIOSH enUS Instructions for Use 2 fr Notice d utilisation 6 es Instrucciones de uso 10 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales S...

Page 2: ...rking is externally legible and positioned on the mask DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially ha...

Page 3: ...ion Standard 29 CFR 1910 134 Failure to do so can result in serious personal injury or death 00821592_1 eps Fig 2 00221592_1 eps 1 Fig 3 00321592_1 eps 2 1 3 Fig 4 01321592_1 eps Fig 5 Positive Fit Ch...

Page 4: ...isinfection times can damage the mask 00421592_1 eps Fig 10 Maintenance Regular service maintenance and pre use checkouts of your CDR 4500 is of the utmost importance to ensure safe use of the device...

Page 5: ...for un used stored mask in original packaging otherwise every 6 months Visually inspect correct function and leak check X X1 Replace exhalation valve disc X Replace speech diaphragm X Visual check by...

Page 6: ...pas respect es il y a un possible risque de mort ou de blessure grave en raison d un danger potentiel ATTENTION Si les mesures de prudence ad quates ne sont pas respect es il y a un possible risque de...

Page 7: ...point peut entra ner des blessures graves ou mortelles 00821592_1 eps Fig 2 00221592_1 eps 1 Fig 3 00321592_1 eps 2 1 3 Fig 4 01321592_1 eps Fig 5 Contr le d ajustage positif Placez la paume de votre...

Page 8: ...92_1 eps Fig 10 Entretien Il est extr mement important d effectuer une r paration et un entretien r guliers de l quipement ainsi que de mener les contr les pr utilisation de votre CDR 4500 a n d assur...

Page 9: ...asques non utilis s et stock s dans leur emballage d origine sinon tous les 6 mois Contr le visuel contr le du bon fonctionnement et recherche de fuites X X1 Remplacement du disque de la soupape expir...

Page 10: ...correspondientes ADVERTENCIA Existe el peligro potencial de muerte o de sufrir lesiones graves si es que no se toman las medidas de precauci n correspondientes ATENCI N Existe el peligro potencial de...

Page 11: ...i n de la respiraci n En caso que no se realice esto se pueden sufrir lesiones o accidentes mortales 00821592_1 eps Fig 2 00221592_1 eps 1 Fig 3 00321592_1 eps 2 1 3 Fig 4 01321592_1 eps Fig 5 Prueba...

Page 12: ...muy alta y una exposici n prolongada a los desinfectantes puede da ar la m scara 00421592_1 eps Fig 10 Mantenimiento La realizaci n de trabajos de mantenimiento y conservaci n regular as como pruebas...

Page 13: ...co Dr ger o certi cado con el nivel II por Dr ger 00721592_1 eps Fig 13 Control visual de v lvula de exhalaci n Sacar la tapa de protecci n del conector de la m scara y revisar cuidadosamente el disco...

Page 14: ...quid chemical warfare agents dispose of the respirator after decontamination V Not for use in atmospheres immediately dangerous to life and health or where hazards have not been fully characterized W...

Page 15: ...15 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Page 16: ...August 2006 Subject to alteration Dr ger Safety AG Co KGaA Revalstrasse 1 D 23560 Luebeck Germany Tel 49 451 8 82 0 Fax 49 451 8 82 20 80 www draeger com Distributed By The Safety Equipment Store www...

Reviews: