Caution: 

 

Two Person Lift Required. PHANTOM Cure Station is a long, heavy object.

• Hot Surface. Do not touch the internal heating unit during or after operation. 
• Disconnect PHANTOM Cure Station from power source when servicing.

Cleaning Information

Over time moisture or evaporative residue may build up inside of the station. Wear appropriate gloves and wipe down 
first with a damp absorbent cloth or paper and then give a final wipe down with a dry absorbent cloth or paper.

IMPORTANT Power Cable Information

Please, ensure that your PHANTOM Cure Station is electrically rated to operate with the AC power available in your 
location. North America voltage: 110 VAC. Europe and Japan voltage: 220 VAC.

• Only use the power cable that was provided with your PHANTOM Cure Station.

• Do not plug the equipment power cable into an electrical outlet if the power cable is damaged. 

• To prevent electric shock, plug the equipment power cable into properly grounded electrical outlets. If the equip-
ment is provided with a 3-prong power cable, do not use adapter plugs that bypass the grounding feature, or remove 
the grounding feature from the plug or adapter. 

• Connect the power cable to a grounded electrical outlet only. 

• If you use an extension power cable, ensure that the total ampere rating of the products plugged in to the extension 
power cable does not exceed the ampere rating of the extension cable. 

• If you must use an extension cable or power strip, ensure the extension cable or power strip is connected to a wall 
power outlet and not to another extension cable or power strip. The extension cable or power strip must be designed 
for grounded plugs and plugged into a grounded wall outlet. 

• If you are using a multiple-outlet power strip, use caution when plugging the power cable into the power strip. 
Some power strips may allow you to insert a plug incorrectly. Incorrect insertion of the power plug could result in 
permanent damage to your equipment, as well as risk of electric shock and/or fire. Ensure that the ground prong of 
the power plug is inserted into the mating ground contact of the power strip. 

• Be sure to grasp the plug, not the cable, when disconnecting equipment from an electric socket.

Summary of Contents for PHANTOM 2.0

Page 1: ...lpine skis and snowboards Traitement de base haute performance pour skis alpins et snowboards Hochleistungs belagsbehandlung f r alpinski und snowboards i EN Update July 2020 Cure Station Formula Form...

Page 2: ...hantom En cas d ingestion ou d exposition prolong e peut causer des dommages au syt me nerveux central aux reins et au c ur Ne pas utiliser si vous tes enceinte ou avez des difficult s respiratoires N...

Page 3: ...tructions pg 12 for correct care of your PHANTOM CSF Each bulk bottle contains 250ml of PHANTOM liquid Disposal If entire contents of individual packets or bulk containers are not used up remaining li...

Page 4: ...with a 3 prong power cable do not use adapter plugs that bypass the grounding feature or remove the grounding feature from the plug or adapter Connect the power cable to a grounded electrical outlet o...

Page 5: ...EN B C D G A E Power Cord Inlet Main Power Switch Preheat Start Cancel Saw Horse Door Limit Switch OPERATION...

Page 6: ...lay current installed firmware version i e 2 49 Fo The door limit switch G may need to be adjusted in out to ensure switch activation while not creating a significant gap in the door seal Do this by a...

Page 7: ...p centered under the lights close the door and press the Start button The cure cycle timer will only be initiated at this point if Ready to Cure is displayed Have the door open for minimum time to ret...

Page 8: ...til base is fully covered and clean Wipe dry with a clean micro fibre towel allowing full evaporation of base cleaner afterwards If base is particularly dirty brush it out and then repeat base cleanin...

Page 9: ...ed at a minimum shop temperature of 58 F 15 C For optimum results bases should be at 75 100 F prior to applying PHANTOM STEP 3 With any binding brakes securely strapped flat or snowboard bindings off...

Page 10: ...l base looks its natural color with no visible white PHANTOM Spray water over the entire ski we recommend a spray bottle of water for this Wipe off with a clean microfiber until dry STEP 4 STEP 5 On a...

Page 11: ...ishing Following the finishing brushing process in Step 5 or 6 polish the bases with a felt roto brush Do 2 passes in both directions i e tip to tail and then tail to tip Take care to move the brush q...

Page 12: ...ottle and close tightly leaving compressed 2 Double bag the bottle s in ziplock bags or other similar freezer bags the packaged bottles in a freezer or fridge and leave long term 3 Remove bottles from...

Page 13: ...rushing Apply in a well ventilated area Store test tubes upside down on top of a paper towel absorbent cloth Servicing Items available by contacting DPS Fuse 10A 250VAC 5X20MM Power Cord 110v Type B I...

Page 14: ...are still wet after 20 minutes curing in the cure station Take the skis board out and using a fresh paper towel wipe down any wet areas Place the skis board back in the Cure Station for another 5 10...

Page 15: ...Station firmware will be sent in an email or a web link Step 4 With the Cure Station power off and main power cord unplugged insert the USB curved side facing up into the inside back left port of the...

Page 16: ...Cure Station Firmware Update folder and find the Firmware Updates within Determine if you have a 3 button or 1 button Cure Station Download the correlating hex file in the 3 button or 1 button folder...

Page 17: ...eration of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Fuse Ratings and Characte...

Reviews: