background image

 

 
INSTALLATION INSTRUCTIONS 

RAB DESIGN LIGHTING INC. 

10/09/2018 

 

RAY8S-LED 

ELECTRICAL SHOCK HAZARD 

READ, UNDERSTAND

, and 

FOLLOW 

these instructions 

before installing the equipment. 

WARNING

SAFETY

 

 

Proper grounding is required to ensure personal safety. 

 

Fixture should be mounted in locations where unauthorized personnel will not readily subject it to tampering. 

 

Do not use this equipment for anything other than its intended purpose. 

 

Servicing this equipment should be performed by qualified service personnel. 

 

Save these instructions. 

 

INSTALLATION 

 

1.

 

Attach the anchor bolts to the concrete with a bolt centred diameter of 
3.62” and the thread should protrude at least 3” from the concrete. 

2.

 

Insert a nut followed by a washer to each anchor bolts. 

3.

 

Place base plate over the over the bolts. 

4.

 

Install wire and tie bracket on the base plate to one of the anchor bolts. 

5.

 

Loosely tighten the flat washers and the nuts onto the anchor bolts 

6.

 

Level the base plate by adjusting the leveling nuts under the base plate. 
Then tighten the upper nuts on top of the base plate. 

7.

 

Place the conduit wires through the wire-tie in the wire-tie bracket, Do the 
connection through the zip-tie and tighten the wire – tie to make sure the 
wires are above the ground level. 

8.

 

Make the wiring connection as per the Wiring diagram. 

9.

 

Place the fixture above the base plate and tighten the four hex head socket 
screws at the bottom of column. 
 
 

 

WIRING 

 

Check that the line voltage is correct. 

 

Connect fixture 

GROUND

 (green) wire to power supply 

GROUND

 (green) wire. 

 

Connect fixture 

WHITE

 wire to power supply 

NEUTRAL

 wire. 

 

Connect fixture 

BLACK

 wire to power supply 

LINE

 wire 

 

 

 

Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box).  Failure to do so could result in serious 
injury or death.  Only qualified electricians should install this fixture and the installation MUST conform to the Canadian 
Electrical Code Part I and all local codes and ordinances.  Ensure that only proper tools, materials, and equipment are used to 
complete the installation. 

Anchor Bolts 

Base Casting 

Riser 

Concrete  

Grade 

Reviews: