9.2
Disassembly
Protective equipment:
Use ear protection
Eye protection
Respiratory protection device
Protective workwear
Protective gloves
1. Rinsing
2. Disconnect the compressed air supply
and material feed. Secure against recon-
nection.
3. Disconnect all lines.
4. Disassemble the spray gun from the sup-
port bracket.
9.3
Disposal
ENVIRONMENT!
Environmental damage caused by
improper disposal
Improper waste disposal threatens the
environment and prevents re-use and
recycling.
– Always dispose of components in
accordance with their characteristic.
– Collect leaked out operating and
auxiliary materials completely.
– Dispose of operating and auxiliary
materials according to the disposal
provisions in force.
– In case of doubt, refer to the local
disposal authorities.
10
Technical data
10.1 Dimensions and weight
Fig. 10: Dimensions
Detail
Value
Length
115 mm
Width
20 mm
Height (without con-
nections)
34 mm
Weight (without con-
nections)
155 g
Nozzle diameter
depending on
design:
0.6/0.8/1.0/1.2 mm
10.2 Connections
Connection
Nominal width
Material
Ø
6 mm (G1/8”-
threads)
Control and atom-
izer air
Ø
6 mm Push-In
(M5-threads)
Minimum cross section
The minimum dimensions required for the
cross section of the air and material feed
lines are as follows:
Technical data
11/2016
EcoGun AS AUTO Mini RS - MSG00007EN
19/28