8
Faults
8.1
Defects table
Fault description
Cause
Correction
No Material
Line pinched or broken
Check the line.
Needle does not open.
Check control air.
Material leaking when
needle is closed.
Needle does not close cor-
rectly.
Check operation of needle. Replace
needle together with the nozzle if
Nozzle soiled or defect.
Clean and check the nozzle. Replace
nozzle with needle if defective
Spray jet too strong in
center.
Too much material
Reduce material feed.
Increase atomizer air pressure.
Material too viscous.
Change material consistency.
Broken spray jet
Not enough material.
Increase material feed.
Decrease atomizer air pressure.
Material too thin.
Change material consistency.
Atomizer air pressure too
high
Decrease atomizer air pressure.
Check external valve of the atomizer.
Sickle-shaped spray jet
Nozzle soiled or defect.
Clean and check the nozzle. Replace
nozzle with needle if defective
Cap nut or nozzle is not
properly tightened.
Uneven spray jet
Nozzle soiled or defect.
Clean and check the nozzle. Replace
nozzle with needle if defective
Material pressure too low.
Increase material pressure.
Feed line pinched or
broken.
Check the feed line.
Needle does not open
fully.
Check control air.
Faults
11/2016
EcoGun AS AUTO Mini RS - MSG00007EN
13/28