39
Crane 4000LE
07-2022
RL6002-003
Chapter 9
Crane 4000LE Wiring, Setup and Troubleshooting Manual
In-ground Motion Assist 360 drive and speed control
Remote control enclosure
Fig. 9.6.1 Night bank switch wiring
9.6 Night bank (option) installation and wiring
33
3
Red
Night bank
inside
33
3
35
3
Night bank
outside
35
3
Inside
Outside
Motion Assist 360
control unit
Red
Blk
Red
Blk
2 conductor cable
18 AWG stranded wire
2 conductor cable
18 AWG stranded wire
Blk
Blk
Red
9.6.1 Night bank switch installation.
1. Locate and install Night bank switches per customer
direction, one on building interior side of door and one
on the exterior side.
• Mechanical installation per manufacturer's
instructions.
TIPS AND RECOMMENDATIONS
Night bank switch installation:
"S" Motion Assist module must be installed.
9.6.2 Night
bank
contact wiring.
1. Use 2 conductor, 18 AWG cable with color code:
• Black
• Red
2. Route cable from each Night bank dry contact to
Motion Assist 360 control unit (Para. 7.2) in Remote
enclosure.
3. Terminate cable wiring in Night bank terminal blocks
as shown in fig. 9.6.1.
9.7 Fault LED installation and wiring
Ø0.23 [5.8 mm]
lens diameter
Ø0.33 [8.3 mm]
flange diameter
Fig.9.7.1
Fault LED RX6013-001
Fig.9.7.2
Fault LED RX6013-001
9.7.1 Fault LED installation.
1. Locate and install Fault LED below or above Mode
switch.
9.8.2 Fault
LED
wiring.
1. Route 2 wires or two conductor cable from Fault LED
to Motion Assist 360 control unit (Ref. Para. 9.1) in
Remote enclosure.
2. Wires terminate in Fault LED terminal block.
1
Fault
LED
VIO
86 85
85
86
85
86
Recommended mounting hole
1.5 mm to 6 mm panel thickness
Ø 0.250”
Red
Blk
Location:
Motion Assist 360
control unit