ED700 Controller Code Information
DISPLAY
S
E
T
O
N
D
N
A
N
O
I
T
I
N
I
F
E
D
N
O
I
T
C
N
U
F
N
O
I
T
C
E
S
LE
Run
Low Energy
Low Energy operation, switch on side of control must also be turned to LE for Low Energy function. Adjusted
according to ANSI 156.19.
PA
Run
Power Assist
Power Assist operator will assist in manual operation but will not open the door.
OCN
Mount Type
OCM
Overhead concealed, direct drive application.
PSH
Mount Type
Push Arm
Push or Out arm application, door swings away from the header.
PUL
Mount Type
Pull Arm
Pull Arm or In arm application, door swings under the header.
LOG
Mon
Log
The controller logs the last 16 unusual
events,
turn dial knob counter clockwise to view. This feature is helpful in
troubleshooting problems. See
Event
at end of form.
ObS
Mon
Obstacles
Total obstacle count up to 255; to reset, turn dial knob counter clockwise. Remember to reset if you adjust
O.Ob, or C.Ob.
CYC
Mon
Number of Cycles
Total number of complete cycles up to 9,999,999 that the
controller
completed. Turn dial knob clockwise to
view complete number.
rEL
Mon
Softward Version
Displays the software release version the controller contains.
AnG
Mon
Angle
Approximate door angle in degrees. Setting and actual opening point must agree for proper operation.
CUr
Mon
Current
The motor current exceeded maximum for too long.
HLd
Misc. Selections
Hold
Power Hold function, adjustable force setting to hold the door against the latch or closed position OFF is spring
tension only.(OFF 0.01 AMPs - 0.70 AMPs)(OFF is default after reset)
PnG
Misc. Selections
Push to Open
Push to open feature opens the door automatically when it is pushed off the latch stop. (Yes - No, default is NO)
OOS
Misc. Selections
Opening
Obstruction
This menu is used to adjust Opening obstruction threshold. Value is displayed in
TIME
. Higher
TIME
means
less sensitivity.(1.5 default, 0.2 - 2.0)
COS
Misc. Selections
Closing Obstruction
This menu is used to adjust Closing obstruction threshold. Value is displayed in
TIME
. Higher
TIME
means
less sensitivity.(0.5 default, 0.2 - 1.1 )
UAL
Misc. Selections
Wall Mask Angle
Menu adjust the angle at which point a swing side door mounted sensor is inhibited. (Default 65°, 60-115°)
OPd
Misc. Selections
Lock Delay
Lock delay function used for doors with locks or panic hardware that have to release before the door opens.
OFF equals no delay.(OFF is default, OFF is 0.1 Sec., 0.1 -
2
.0 Seconds.)
OCd
Misc. Selections
Occupied Delay
How long the door stops after an obstacle or presence signal is received. ( 2 Sec default, 0.1 - 10.0 Sec.)
dEC
Misc. Selections
Deceleration
How quickly the door shows at back check; the higher the number the faster the door slows. (50 Default, 10-
1
27)
PCE
Misc. Selections
Power Close
Engaged
("no" or "yes") Turns power close on or off. ("no" is default after reset)
PCA
Misc. Selections
Power Close Angle
(off or 1 - 30 degrees) - Sets the angle the power close turns on at. (20 is default after reset)
PCd
Misc. Selections
Power Close Time
Delay
(00.1 - 10 seconds) - Sets the time delay the power close starts after it achieves the proper power close angle.
(4 is default after reset)
PCC
Misc. Selections
Power Close
Current
(off or 0.01 - 1.00 Amps) - Sets the power closing amps in PCd area.(1.00 is default after reset)
CLC
Misc. Selections
Power Boost
"Closing Current" (Off, or 0.01 - 1.00 Amps) - Sets the closing current while the door is at
"any angle"
of it's
closing cycle.(0.50 is default after reset)
rSt
Misc. Selections
Reset
Resets all parameters back to factory defaults.
Reset the control before the learn cycle on new installs,
or
use the learn function to force a learn cycle on existing installations.
ALL
Learn
Learn
The opener needs to do a full learn cycle, required on initial install see, rSt.
CYC
Learn
Cycle
The operator needs to do an open and closing cycle. The door will cycle after initial tune in until door is turned
OFF and back ON.
rdY
Learn
Ready
The learn cycle is completed and the operator is ready.
- - -
Event
No other event in the log.
bad
Event
BAD
A variable in the control is out of established limits.
Cob
Event
Closing Obstacle
The door encountered an obstacle while opening. See COS parameter in Misc. Selections.
CUr
Event
Over Current
The motor current has exceeded limits for extended period.
DIr
Event
Direction
The motor is wired backwards.
EnC
Event
Encoder
The control is not receiving encoder information.
ENE
Event
Breakout
An emergency link was broken. Breakout switch or Smoke detector activation.
FAI
Event
Controller
The control box has failed to function.
HEA
Event
Overheat
The motor overheated.
LOC
Event
Locked
The door encountered an obstacle at latch stop.
Ntr
Event
Motor
The motor is not connected, or is open.
OOb
Event
Opening
Obstruction
The door encountered an obstacle while opening. See OOS parameter in Misc. Selections.
PUP
Event
Power Up
Automatic power up after a bad value was detected.
Set
Event
Set-up
The operator is not set-up; a learn cycle is needed. If ready does not appear after a learn cycle , reset the
control and try again.
SnG
Event
Presence Sensor
The swing side door mounted sensor was activated.
SUP
Event
Set-up
The operator is not set-up; a learn cycle is needed. If ready does not appear after a learn cycle , reset the
control and try again.
to
Event
Time Out
A state lasted longer then expected.
If this unit is installed as a
LOW ENERGY
Operator, it is the installer's responsibility to adjust the operating
parameters of the operator as to
NOT EXCEED
those in the
BHMA/ANSI 156.19
standard.
If these parameters are exceeded, additional safety devices MUST be installed to satisfy the requirements that
are stated in the
BHMA/ANSI 156.10
standard for
FULL POWER DOORS.
!