ED700
Low Energy
Automatic Swing Door
DORMA
21
DORMA AUTOMATICS, Inc.
924 Sherwood Drive
Toll-Free: 877-367-6211
Lake Bluff, IL 60044
Fax: 877-423-7999 DL3038-010 Rev. B
6
/08
E-mail:
Subject to change without notice
•
Run a “Learn” cycle on both controllers. It’s
easier if they are done separately.
If it’s desired that the doors open and/or
close differently, continue on this side of the
page. If not, skip to the top of the column to
the right.
To have the doors open at different times
set the OPD Open Delay parameter in
miscalenous adjustments on the door you
want to delay.
To have the doors close at different times
increase the Hold Open time or slow the
Closing Speed of the door you want to
close last. To assure synchronization of the
doors an external time delay may be
required to assure that the time delays
remain constant.
•
When both openers are ready, trigger an
automatic opening and, as the doors are
opening, block one of doors. The other
door will stall. Once it stalls let the door
you were holding go and both door will
open. Once closed trigger the door again
and stop the opposite door.
After completing both doors opening cycles
complete the same process for the closing
cycles.
•
This will let each opener tell the other of
having detected an obstacle, so that each
will know of the presence of the a second
door. Knowing that, the operators will
extend the Hold-Open time to ensure that
both doors remain in synchronization.
Setting Up Simultaneous Doors
Setting Up Semi-Independent Doors
The purpose of the this set-up is to synchronize two
side-by-side doors for semi-independent operation.
This means that the doors will open and close at the
same time, but will react to obstacles independently.
Connecting the Controllers
•
Program the two controllers identically
(for coordinated doors - one must close first -
increase slightly the Closing Delay of the controller
for the door that must close last)
•
Connect the grounds of the two controllers
together.
•
Connect one door’s presence sensor to the
controller for that door.
•
Connect the push plates to both controllers in
parallel
•
Let each controller power its presence sensors
•
Connect a single program switch to both controllers
in parallel.
•
Power the controllers from the same AC power
source.
Push
Plate
Header
Presence
Swing
Presence
Approach
Presence
Safety
Beam
+24V
TRIGGER
COM
+24V
HEADER
DATA
COM
+24V
SWING
COM
+24V
APPR.
COM
+24V
BEAM
COM
C
O
N
T
R
O
L
L
E
R
1
Header
Presence
Swing
Presence
Approach
Presence
Safety
Beam
+24V
TRIGGER
COM
+24V
HEADER
DATA
COM
+24V
SWING
COM
+24V
APPR.
COM
+24V
BEAM
COM
C
O
N
T
R
O
L
L
E
R
2
OFF
GND
H.O.
Mode
Switch
OFF
GND
H.O.