ED700
Low Energy
Automatic Swing Door
DORMA
25
DORMA AUTOMATICS, Inc.
924 Sherwood Drive
Toll-Free: 877-367-6211
Lake Bluff, IL 60044
Fax: 877-423-7999 DL3038-010 Rev. B
6
/08
E-mail:
Subject to change without notice
Technical Data
Operator
Line
Input
100
to
125V
AC
, 60 Hz, 2 A max.
Power supply for external sensors
24 V
DC
, 0.8 A
Fuse
2
A
fast
blow
Ambient Temperature
77
°F(25
°C)
Opening time to Back-Check
2.8 s 8 s
Closing time to Latch-Check
3.0 s 7.5 s
Delay before Opening
0 s 3 s
Delay before Closing
5 s 25 s
Back-Stop
Angle
60°
120°
Back-Check-Angle 50°
120°
Latch-Check-Angle 10°
30°
Wall-Mask-Angle
60°
115°
Extra Power Hold Torque
40 ft-lb 240 ft-lb
Door
height
84"
102"
Door weight
60 lbs (27 kg)
200 lbs (90 kg)
Door mount - single
Push or Pull
(Surface Applied)
Door
width
37"
49“
Door mount - pair Push
or
Pull
(Surface
Applied)
Door
width
62"
98"
Adjustments
min. max.
Door
min.
max.
Controller Technical Data
Power input
Connector
2-piece terminal block
Line Input
100 to 125Vac, 60 Hz, 2 A max.
Fuse
2 A, fast (5mm x 20mm)
DC power out
24 Vdc, 800 mA out, always on,
short circuit protected, not regulated
Control inputs
Connector
2-piece terminal blocks
Active low inputs:
Open-Trigger (radar or push plate)
Presence, jamb mounted sensor
Safety Side, door mounted sensor
Approach Side, door mounted sensor
Hold-Open
Off
Safety Beam Sensor
Polarity
active low or closed contact to
ground
Active threshold
< 0.8 Vdc
Inactive threshold
> 2.0 Vdc
Closed contact current
10 mA surge, 1 mA steady
state
Open circuit voltage
5 V
ESD protection
±5 KV, human body model
Overvoltage protection
±5 Vdc or 5 Vac, continuous,
with respect to GND
Smoke (Kill) link input:
Polarity
normally closed contact to
GND
Closed contact current
2 mA
ESD protection
±5 KV, human body model
Overvoltage protection
±5 Vdc continuous, with
respect
to
GND
Indicators
1 LED/Sensor, 3-Digit Display
1-8 +24V
9
Electric Strike
-Output
10
Data (Zone)
-Output
11
Trigger (or radar or push plate)
-Input
12
Presence (jamb mounted sensor)
-Input
13
Safety Side (door mounted sensor) -Input
14
Approach Side (door mounted sensor) -Input
15
Safety Beam
-Input
16
Kill (Smoke) link
-Input
17-24 GND
Program switch
3
Hold
Open
-
Input
2 GND
1
OFF
-
Input
Breakout
1
Breakout
Switch
-(N.C.)
2 GND
Motor
1 M+
2 M-
Power Input
1 Neut.
2 Earth
Ground
3
Hot
100 to 125 VAC, 60 Hz, 2 A max.
Terminal Designations