56
Batch Program 1
Two Speed Net Weight Fill with Manual Feed
This batch program allows a one or two speed container fill directly on a scale platform.
The container placed on the scale platform can be detected by programming the
minimum and maximum container weight into setpoints 3 and 4 as seen below in the
Batch Program Configuration table. The container detection will prevent filling without
a container present or when a filled or partially filled container is present.
This batch program does not offer a stop or pause once filling has commenced. If a
hazardous condition could possibly exist, an emergency stop button should be wired
directly to the relay output power.
BATCH PROGRAM CONFIGURATION
Batch Control
Digital I/O
Controls
Setpoint
Front Panel
Pushbuttons
Batch Pause / Restart
MENU
Batch Start
F1
Fast Fill or Ingredient One
Output 1
Setpoint 1
Slow Fill or Ingredient Two
Output 2
Setpoint 2
Manual Fill
Output 3
F2
Minimum Container Weight
Setpoint 3
Maximum Container Weight
Setpoint 4
Batch Step
Batch Function
1
Place empty container on scale platform. Container weight must be
between Setpoint 3 and Setpoint 4 weight values in order for the batch
program to start.
2
Press F1 to start batch program
3
Scale Tares
4
Output 1 is closed until Setpoint 1 weight value is reached
5
Output 1 opens
6
Batch Delay Pause
7
Output 2 is closed until Setpoint 2 weight value is reached
8
Output 2 opens
9
Batch Delay Pause
10
Scale Accumulates weight in container, Counter is advanced
11
Remove filled container
ANY
Press F2 to manually fill. This function is available any time the
indicator is on.
Summary of Contents for GuardianXL