34
Batch Cfg F1/F2
A batch mode control parameter. This parameter enables or disables the F1/F2
Pushbuttons while in batch mode.
On
Enables use of F1/F2 batch control pushbuttons.
Off
Disables use of F1/F2 batch control pushbuttons.
Batch Program
A batch mode control parameter. This parameter selects the pre-programmed
batch program to load into memory. See Chapter 7 Batch Programs for
implementation of batch programs.
------
No Batch Selected – Scale is in Normal Weigh Mode
Batch 1 Two Speed Net Weight Fill with Manual Feed
Batch 2 Two Speed Hopper Fill with Manual Dump and Fill
Batch 3 Three Speed Fill with Automatic Dump and Auto Repeat
Batch 4 Three Speed Loss In Weight with Manual Dump
Batch Delay Time
A batch mode control parameter. This parameter allows a delay to be inserted
into a batch program.
0-99
Press CLEAR to Erase Previous Setting. Enter Desired Time from 0-
99 Seconds.