59
Batch Program 3
Three Speed Fill with Automatic Dump and Auto Repeat
This batch program allows a one, two or three speed fill and dump system with an
automatic repeat. This program fills directly into a tank or hopper on a scale platform.
BATCH PROGRAM CONFIGURATION
Batch Control
Digital I/O
Controls
Setpoint
Front Panel
Pushbuttons
Batch Start
Input 2
Batch Reset
F1
Batch Pause / Restart
F2 or MENU
Fast Fill or Ingredient One
Output 1
Setpoint 1
Slow Fill or Ingredient Two
Output 2
Setpoint 2
Trickle Fill or Ingredient Three
Output 3
Setpoint 3
Dump Hopper or Tank
Output 4
Setpoint 4
Batch Step
Batch Function
1
Zero scale
2
Scale Accumulates weight in hopper, Counter is advanced
3
Output 4 is closed until Setpoint 4 weight value is reached
4
Output 4 opens
5
Batch Delay Pause
6
Output 1 is closed until Setpoint 1 weight value is reached
7
Output 1 opens
8
Batch Delay Pause
9
Output 2 is closed until Setpoint 2 weight value is reached
10
Output 2 opens
11
Batch Delay Pause
12
Output 3 is closed until Setpoint 2 weight value is reached
13
Output 3 opens
14
Batch Delay Pause
15
Batch automatically returns to batch step zero