61
Batch Program 4
Three Speed Loss In Weight With Manual Dump
This batch program allows a one, two or three speed loss in weight with a dump. This
batch program requires negative setpoints to be entered.
BATCH PROGRAM CONFIGURATION
Batch Control
Digital I/O
Controls
Setpoint
Front Panel
Pushbuttons
Batch Pause / Reset
MENU
Start Batch
F1
Fast Fill or Ingredient One
Output 1
Setpoint 1
Slow Fill or Ingredient Two
Output 2
Setpoint 2
Trickle Fill or Ingredient Three
Output 3
Setpoint 3
Batch Step
Batch Function
1
Press F1 to start batch
2
Tares Scale
3
Output 1 is closed until Setpoint 1 weight value is reached
4
Output 1 opens
5
Batch Delay Pause
6
Output 2 is closed until Setpoint 2 weight value is reached
7
Output 2 opens
8
Batch Delay Pause
9
Output 3 is closed until Setpoint 2 weight value is reached
10
Output 3 opens
11
Batch Delay Pause
ANY
To refill hopper or tank Press F2 Output 4 is closed
Dump Container or Reload Hopper Modification
This will configure F2 to manually trigger Output 4 to dump container or reload hopper.
Parameter / Pushbutton
Parameter Selection
Press MENU then 8 (I/O)
“OUTPUT / FUNCTION”
OUT4
Press TARE (
)
“ENABLE OUT/FUNC”
o4 hi
Press TARE (
) until
“PUSHBUTTON F2”
PrESS
Press MENU
Summary of Contents for GuardianXL
Page 2: ...1...
Page 8: ...7...
Page 16: ...15...
Page 18: ...17 Figure 3 1 Motherboard Load Cell Connection and Jumper Location...
Page 22: ...21...
Page 38: ...37 REMOVE THIS PAGE AND REPLACE WITH FIG4 7 PDF PRINT B SIZE Figure 4 7 Setup Mode Menu...
Page 39: ...38...
Page 55: ...54...
Page 84: ...83...