Fusion Hybrid Gas Condens
60
22
TECHNICAL CHARACTERISTICS
Unit
FUSION HYBRID GAS
CONDENS 24
FUSION HYBRID GAS
CONDENS 24 /160
Code
D9.24.HDX120
D9.24.HDX160
Boiler Type
Condensing
Heating and hot water production
Gas Circuit
Gas Type
G20 G25 G31 G20 G25 G31
Gas Supply Pressure
mbar
20 25 37 20 25 37
Gas Consumption at Maximum
m³/h
2,49 2,83 0,96 2,49 2,83 0,96
Gas Consumption at Minimum
m³/h
0,36 0,43 0,14 0,36 0,43 0,14
Modulation Range
1:10
1:10
Efficiency
Gas Type
G20
G25
G31
G20
G25
G31
(80/60 °C) Efficiency at Maximum Heat Output
%
97,69
97,36
97,57
97,69
97,36
97,57
(50/30 °C) Efficiency at Maximum Heat Output
%
105,15
105,45
103,01
105,15
105,45
103,01
Efficiency at 30% load at 36/30 °C
%
108,0
107,70
105,81
108,0
107,70
105,81
Heating Circuit
Gas Type
G20
G25
G31
G20
G25
G31
Maximum Heat Input (Qn) (PCI)
kW
24,3
24,3
24,3
24,3
24,3
24,3
Minimum Heat Input (Qn) (PCI)
kW
3,5
3,5
3,5
3,5
3,5
3,5
Maximum Heat Output (80/60 °C) (Pn)
kW
23,7
23,7
23,7
23,7
23,7
23,7
Minimum Heat Output (80/60 °C) (Pn)
kW
3,2
3,2
3,2
3,2
3,2
3,2
Maximum Heat Output (50/30 °C)
kW
25,3
25,3
25,0
25,3
25,3
25,0
Minimum Heat Output (50/30 °C)
kW
3,6
3,6
3,5
3,6
3,6
3,5
Temperature Selection Range (Heating)
ºC
25-80
25-80
Operating Pressure (Maximum) (PMS)
bar
3
3
Operating Pressure (Minimum)
bar
0,5
0,5
Expansion Tank Useful Volume
L
8
8