37
Nº.
Parameter
Range
P23
Cycled time for pump activation: zone (1/1 min.)
1 ~ 10
0
P24
Child protection
0 ~ 1
0
P25
Height offset parameter (1:100 m)
0 ~ 20
0
P26
Water hammer delay (s)
0 ~ 3
0
P28
Automatic display shut-down (s)
0 ~ 120
45
P31
Reserved
80 ~ 160
120 (GN)
120 (GLP)
P32
Reserved
P33 ~ 255
160 (GN)
148 (GLP)
P33
Reserved
30 ~ 60
32 (GN)
31 (GLP)
P34
Reserved
0 ~ 100
50
P35
Reserved
0 ~ 100
30
P36
Reserved
0 ~ 100
50
P37
Reserved
3 ~ 3
3
P38
Anti-frost activation temperature adjustment (ºC)
0 ~ 10
5
P39
Heating pump post-circulation (1=10 s)
0 ~ 99
18
P40
Heating activation delay after DHW (1 = 10 s)
0 ~ 60
12
P41
Reserved
0 ~ 1
0
P43
Reserved
0 ~ 30
0
P44
Reserved
0 ~ 1
1
P45
Anti-legionnaire's disease function (ºC)
54 / 55 ~ 80
54
P46
Reserved
0 ~ 1
1
P47
∆
Time between heating flow and return for pump
modulation
10 ~ 40
20
P48
Pump operation mode
0 ~ 1
0
P49
Reserved
0 ~ 99
0