9
4
INSTALLATION INSTRUCTIONS
The
Fusion Hybrid Gas Condens
module can only be installed in combination with a heat pump from
the
DUAL CLIMA
line, supplied by
DOMUSA TEKNIK
. Therefore, for its operation, these devices should
be connected to each other, both hydraulically and electrically. In this section, the necessary
operations for said connection are described in detail.
The module must be installed by personnel auhtorised by the MInistry of Industry, in compliance with
the applicable laws and regulations. In general, these laws and regulations are the "Basic Gas
Installation Standards", the "Heating, Air Conditioning and Domestic Water Installation Regulation"
and all other local regulations.
The module is suitable for heating water to a temperature below boiling point at atmospheric
pressure. It must be connected to a heating installation and/or a domestic hot water distribution
network, which must always be compatible with its performance and power.
This appliance should only be used for the purpose for which it has been expressly designed. Any
other use is considered unsuitable and therefore hazardous. The manufacturer shall not be considered
liable under any circumstances for damage caused by unsuitable, erroneous or unreasonable use.
Remove all the packaging and check that the contents are complete. In case of doubt, do not use the
boiler. Contact your supplier. Keep the packaging elements out of reach of children, as they can be
dangerous.
When you no longer wish to use the module, disable the parts that could represent a potential hazard.
4.1
Location
The module must be located in a sufficiently ventilated area, with openings directly onto the
outside of the building (as required in the Gas Installations Regulation). It must be located so that
the air grilles on the premises are not obstructed and normal boiler maintenance is possible even if
it is placed between items of furniture.
DANGER
It is not necessary to keep a distance between the appliance and objects made of combustible
materials, since the temperature of the device cannot exceed the maximum permissible flow
temperature in heating mode if the device operates with its nominal heat output.
Anyway, it is recommended not to install it near papers, newspapers, magazines or any flammable
object.
Do not install the module near household waste.
Avoid using explosive and easily flammable substances in the room