Fusion Hybrid Gas Condens
54
17.2
Adjustment process
The CO
2
value should be adjusted as follows.
Make sure that the air intake pipe of the module is fully closed and that the sealing is
ensured during calibration.
Make sure that all radiator valves are open during adjustment, or if necessary, the
calibration process will be interrupted if the module reaches the maximum
temperature limit.
Press the
MODE
and
RESET
buttons simultaneously until the circle is
completed.
After releasing the
MODE
and
RESET
buttons, press the button (
)
to adjust the heating temperature before 3 seconds have elapsed.
The letters
Ma-nu
will appear on the display for approximately 60 s.
During this time, the module makes several ignitions.
Do not touch the module and do not change gas pressure during
this time.
Once the module stabilises, the P0 value "Minimum power" will
appear on the display.
Check the O
2
level and use the navigation buttons so that the O
2
level is adjusted to the rated values indicated in the table of
measurement values.
Press the button to adjust the heating temperature (
) until the
circle is completed.
The P0 value is registered, and the module will change its position to
"Ignition power"
Once the module stabilises, the P1 value "Ignition power" appears on
the display.
Check the O
2
level and use the DHW temperature adjustment
buttons so that the O
2
level is adjusted to the rated values indicated
in the table of measurement values.
Press the button to adjust the heating temperature (
) until the
circle is completed.
The P1 value is registered, and the module will change its position to
"maximum power"