52
999805002 - 09/2018
Repositioning
User Information
Load-bearing tower Staxo 40
Lifting by crane
Preparation
Repositioning towers with no
superstructure
Secure the head units so that they cannot be
lifted out
➤
Push a Staxo 40 anti-dropout lock over the nut and
fix it by closing the safety catch on the frame.
Secure the base units to prevent them
dropping out
➤
Push a Staxo 40 anti-dropout lock over the nut and
fix it by closing the safety catch on the frame.
Link the frames in a crane-handling-safe
manner
➤
Use Staxo 40 tube connectors d48.3mm to make
crane-handling-safe links between the frames at
every joint.
Repositioning operation
NOTICE
▪
The max. height of towerframe unit that can
be lifted in one piece is 11
m
▪
Max. weight of tower for repositioning is
1000
kg. The critical factor here is the load
carrying capacity of the anti-dropout lock
and of the safety-catch bolt (5
kN is permis-
sible here in each case)
▪
Max. weight of tower for lifting the tower into
the upright and placing it on its side is
700
kg (see the section headed 'Horizontal
assembly')
WARNING
Danger from loose and unsecured parts.
➤
Observe the following points before lifting!
E
Staxo 40 anti-dropout lock
E
Staxo 40 anti-dropout lock
98024-282-03
E
98024-214-01
E
H
Staxo 40 tube connector D48.3mm
CAUTION
➤
Only attach the lifting chain to a frame node,
not to the diagonal cross or the U-bracket!
Spread-angle β max. 30°.
While the tower is being lifted, there must
NOT be any loose parts, tools or other items
on it!
98024-220-01
H
H
98024-282-02
98024-282-01
b