26
999805002 - 09/2018
System description
User Information
Load-bearing tower Staxo 40
Fitting brackets to the Staxo 40 frame 1.20m
All frames arranged with horizontal profile at top = pull-
point and pressure point of bracket are supported =
Staxo 40 frame strut 1.40m is not needed.
Fitting brackets to the Staxo 40 frame 1.20m
All frames arranged with horizontal profile at bottom =
pull-point of bracket is not supported = Staxo 40 frame
strut 1.40m is needed.
Fitting brackets to the Staxo 40 frame 1.80m
Upper frame has horizontal profile at top, lower frame
has horizontal profile at bottom = pressure point of
bracket is not supported = Staxo 40 frame strut 1.40m
is needed.
Close-up showing how to attach the Plumbing
strut IB
To prevent tower tip-up, a Plumbing strut IB with Strut
shoe EB must be mounted to every frame that has a
bracket attached to it, and this plumbing strut must be
fixed to the ground with a Doka express anchor
16x125mm.
a ... max. 16 cm as stipulated in EN 12812
98024-275-01
B
A
H
F
I
98024-276-01
B
A
H
F
E
I
A
Staxo
40 bracket 90cm
B
Handrail post XP 1.20m or Staxo 40 4-way screw-jack head /
Screw-jack U-head
E
Staxo 40 frame strut 1.40m
F
Plumbing strut IB and Strut shoe EB
H
Diagonal cross 9.xxx
I
Screw-on coupler 48mm 95
F
Plumbing strut IB and Strut shoe EB
I
Screw-on coupler 48mm 95
98024-277-01
B
A
H
F
E
I
a
98024-275-02
F
I