User Information
Load-bearing tower Staxo 40
Horizontal assembly
37
999805002 - 09/2018
Head zone
Fitting the head unit
➤
Insert the head unit and secure it with Staxo 40 anti-
dropout lock.
h ... max. 11 m
b ... Extension length of screwjack base units when tower is lifted into the upright: max. 30
cm
J
Head unit
K
Staxo 40 anti-dropout lock
98
1
024-21 -02
K
J
WARNING
Loads that are applied non-centrally can cause
overloading of the system.
➤
Ensure that all loads are applied centrally!
9776-102-01
F
Diagonal cross
h
F
F
F
b
98
1
024-21 -01