DPC Touch User Manual
31
9.9
Connection of Stanley Alpha and Kappa tools
DPC
Touch
Stanley Alpha/Kappa
I/O adaptor
(DB44 male to DB9 female and DB25 female)
I/O port
Input/Output
Assigned signal
DB9 pin №
Stanley pin
№
Signal
Output 1
Torque Select 1
1
P
Select Job (bit)
Output 2
Torque Select 2
2
R
Select Job (bit)
Output 3
Torque Select 3
3
S
Select Job (bit)
Output 4
Tool Disable
4
M
Disable Tool
Input 8
D_Motor_Run
5
C
Tool Running / Trigger
Input 9
Tool Alarm
6
K
Cycle NOK
Input 10
D_Fastening_OK
7
J
Cycle OK
IN_COM
8
V
0V DC
OUT_COM
9
B
24V DC
NOTE:
Select DC tool interface in DPC Touch operating settings.
In order to use 24V supply from Stanley controller, short connect pins A and B. In this case DPC Touch
will be powered by Stanley controller. Don’t connect DPC T
ouch to external power in this case.
To decouple DPC Touch power supply and I/O external power supply, cut the bridges (15)-(35) and
(30)-(31) in the DB44 connector of the I/O adaptor in order to disconnect 24V power supply.