DPC Touch User Manual
22
7.5
Network
Network communication is not enabled in firmware v.0.2.8
7.6
Other
Real time m
onitoring of encoders and I/O’s (screen 1 of 4)
This interface helps to verify if encoders function correctly. It also helps to check status of input
signals and to force output signals to test wiring.
Touch screen calibration (screen 2 of 4)
Press on
Start
button to enter into touch screen calibration mode. Press and hold indicated positions
for 2 seconds in order to calibrate the screen.
ATTENTION
: if calibration is not correctly performed, the touch screen may become unresponsive. In
this case turn off the controller, take out the SD card, access the SD card from your computer and
delete the following file:
SD:\system\setting\Setting_posi.dat
Sounds (screen 2 of 4)
Adjust the volume by using the slide bar.
Select desired sounds for Position Ok, Alarm and Cycle complete signals. Activate sounds to be used.
Date and time (screen 3 of 4)
Adjust current date and time. The controller is equipped with internal battery to keep this data.
Language (screen 3 of 4)
Select language of the graphical interface. Available languages in firmware v.0.2.8:
English, French, German, Spanish
Password (screen 4 of 4)
Enter the new password and press Set.
Default factory password is “0”.
NOTE:
If the password is lost, turn off the controller, take out the SD card, access the SD card from
your computer and delete the following file:
SD:\system\setting\Setting_posi.dat
After rebooting, the controller will be reset to default factory settings.
Controller reset to factory settings (screen 4 of 4)
Enter “77”
to reset the controller to factory settings. Saved jobs will not be deleted.
Firmware version (screen 4 of 4)
Current firmware version of the controller. Upgrade the firmware regularly to keep the controller up