DPC Touch User Manual
14
6.2
Logical Input step creation
While in Job modification screen, tap on LOGICAL IN button. The Logical In step creation screen will
appear.
Select an available input from the list of Inputs. If an Input was assigned for a specific function in
Input settings it is not available to be used as a logical signal.
Select the type of the signal. There are four types of input signals:
-
Active High
: for this type of signal it is necessary to detect a transition from 0 to 1.
-
Active Low
: for this type of signal it is necessary to detect a transition from 1 to 0.
-
Status High
: for this type of signal it is enough to detect if the signal is equal to 1.
-
Status Low
: for this type of signal it is enough to detect if the signal is equal to 0.
Logical input step is completed if the corresponding input signal matches the condition of the
selected signal type.
If two or more signals are selected, then AND condition will be applied for selected signals to
complete the step.
Press SAVE button to save the step or CANCEL button to quit programming without saving changes.
6.3
Logical Output step creation
While in Job modification screen, tap on LOGICAL OUT button. The Logical Out step creation screen
will appear.
Select an available output and its type from the list of Outputs. If an Output was assigned for a
specific function in Output settings it is not available to be used as a logical signal.
There are two types of output signals:
-
Continuous ON
: the signal is continuous until it is deactivated in the next Logical Out step. To
deactivate the signal, create a new Logical Out step and deselect the corresponding signal.
-
Impulse
: the signal is an impulse with defined duration. Duration of the signal is defined in
ms.
Multiple output signals can be used in the same Logical Out step.
Press SAVE button to save the step or CANCEL button to quit programming without saving changes.
6.4
Delay step creation
While in Job modification screen, tap on DELAY button. The message step creation screen will
appear.
The controller will stay on hold for the defined time. Delay step can be used to manage timing
between Logical In and Logical Out steps or between messages.
Press SAVE button to save the step or CANCEL button to quit programming without saving changes.