DPC Touch User Manual
27
9.5
Connection of DOGA low voltage tools GX/GY/DO/GA
Two tools can be simultaneously connected to corresponding ports DR1 and DR2
DPC
Touch
DOGA GX/GY/DO/GA*
RJ45 I/O port 1 and 2
RJ45 I/O port
Signal
RJ45
pin №
RJ45 pin
№
Signal
Torque Up input
2
2
Torque Up output
Motor Run input
3
3
Motor Run output
Driver Lock output
5, 6
5, 6
Driver Lock input
24V
4
4
24V
*Controllers XT-30D, XS-38D, XS-40D, XS-35D, XT-35D
NOTE:
Select GX/GY/DO/GA tool interface in DPC Touch operating settings.
The tool is locked by short connecting contacts 5 and 6.
ATTENTION!
Use only straight RJ45-RJ45 cable (not crossed).