9024-065-Q-8-16
26
UL 325 Terminal Wiring
1
2
3
4
5 6
7 8 9 10
Closed Gate
Wall
Wireless Note:
Refer to the
instruction sheet that comes
with the receiver/transmitter
for more specific wiring and
mounting instructions.
Wiring Note:
Receiver
can be wired directly to
main terminal if desired.
Close
Edge
Open Edge
Mount transmitter on gate.
Filler Post (If necessary)
Edge
Transmitter
Power is limited
to 250 mamps.
Coax Antenna Kit
P/N 1514-073
Com
24 Volt
3-Pin
Remote
Terminal
24 VAC Receiver
Place receiver in operator.
20-Pin
Main
Terminal
To #1
To #3
1
2
3
Open Beam
IMPORTANT:
Photo sensors must use
Normally Closed (NC)
contacts with the
beam set for light operate (relay
activated when beam is not obstructed).
Only 1 monitored Device can be connected to each
input. An
OPTIONAL
Expansion Kit (sold separately)
will allow connection for additional devices.
Connect ONLY MONITORED
devices to UL 325 terminal.
Close
Edge
Open
Edge
Open
Beam
Wireless Reverse Edge Sample Setup - Single Receiver
Edge transmitter
mounted on gate.
Ground (Common)
Ground (Common)
CLOSE Edge/Beam REVERSE (Switch 4)
OPEN Edge/Beam REVERSE (Switch 3)
CLOSE Beam REVERSE (Switch 2)
OPEN Beam STOP (Switch 1)
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
DIP-switches
1, 3 and 4
MUST
be
ON
.