9024-065-Q-8-16
22
This feature allows long gates to partially open when a fully open gate is not required for normal use. The FULL open limit
switch
MUST
first be set before adjusting the partial open gate position. When the operator’s
inherent reversing sensor
gets
activated during the gate’s
closing cycle
, it will always reverse the gate to the
FULL OPEN
limit switch setting, even when the
partial open feature is being used. When using the “Partial Open” feature,
the operator’s opening
device MUST
be connected to the main terminal #8
.
See page 29 for opening device wiring information.
3.3 Limit Switches
Lock-Plate
Push
Pu
sh
A
B
Limit-Nut
Limit-Nut
Partial Open
Sensor
Magnet
Clip
Adjustment
Nut
“Open”
Limit Nut
Lock-Plate
Side View of Partial Open Assembly
Magnet MUST align with partial open sensor.
A
B
Partial Open Assembly
Push
and hold the
lock-plate away
from the limit-nuts.
Rotate the limit-nuts to the
desired gate
FULL
open and close
positions. After adjusting, make sure the
lock-plate is engaged in the slots on the
limit-nuts to prevent them from rotating.
Loosen
adjustment nut
to position the partial
open assembly to stop the
opening gate at a desired
“Partial Open” position.
Partial Open Feature
Full Open and Close Limits MUST be Set
“Opening Direction”
SW 1 - Switch - 1
Note:
SW 1,
Switch 1
- Secondary operator
“Opening Direction” will be set the opposite
of SW 1, switch 1 on primary operator when
using bi-parting gates.
Limit
Switch
Limit
Switch
Adjustment Nut
C
C
AFTER
the full open limit has been set, attach the
Magnet Clip to the
“Open”
limit nut and align it with
the partial open sensor (See below).
DO NOT
re-adjust
the limit nut. Use the partial open assembly for adjustment only.
Note:
Magnet clip must be removed before re-adjusting the open limit nut.
Note:
Limit/Alarm Plug P3 MUST be connected to the
circuit board or operator will NOT function.
The operator normally stops a cycling gate using the open and close limits. If
the limits have not been set, the gate could continue beyond its full open and
close positions, damaging the gate and operator.
DO NOT
allow this to occur!
1
2345678
ON
SW1
1
2345678
ON
SW1
Opening direction
using
ON
setting.
Opening direction
using
OFF
setting.