9024-065-Q-8-16
Sec:A2
Quick Guide - 1
QUICK GUIDE: DIP-Switches
See page 21 for more information about DIP-switches.
Reset button on circuit board
MUST
be pressed before new DIP-switch settings will take affect.
Switch
Function
Setting
Description
SW 1 (Top 8 DIP Switches)
Operator
Opening
Direction
OFF
ON
OFF
ON
OFF
ON
OFF
ON
6-
OFF
6-OFF
6-ON
6-ON
7-
OFF
7-ON
7-OFF
7-ON
Auto-Close
Timer
Accessory Power/
Maglock Power
Relay:
Main Terminals
13 and 14
1
2
3
4
5
8
6 and 7
The output wired to main terminal 4 becomes the output from the exit loop detector
plugged into the EXIT Loop port.
Normal Setting.
Main terminal 4 is a normal FULL open input.
Auto-close timer is
OFF.
Manual input required to close an open gate.
Normal Setting.
Auto-close timer is
ON
. Adjustable from 1-23 seconds.
500 mA
Constant power
for accessories connected to main terminal 12.
Normally Closed power
for Maglock connected to main terminal 12.
OFF
ON
Normal Setting.
Quick close feature is
OFF
. Auto-Close timer functions normally.
Quick close feature is
ON
. Opening gate will stop and close as soon as all reversing
inputs (Reverse loops, photo sensors) are cleared regardless of the distance the
gate has opened. Any Auto-Close timer setting overrides to 1 sec.
OFF
ON
Main terminal 10 is a REVERSE input.
DO NOT USE
for the 9024.
Main terminal 10 is a SHADOW loop (Swing gates ONLY)
Normal Setting.
Relay activates when gate is at open limit.
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates during opening and closing cycle.
1-OFF
1-OFF
1-ON
1-ON
2-OFF
2-ON
2-OFF
2-ON
Select
Operator
Type
1 and 2
Slide Gate Operator
DO NOT USE
for the 9024.
Swing Gate Operator
DO NOT USE
for the 9024.
Barrier Gate Operator
DO NOT USE
for the 9024.
Overhead Gate Operator
Switch
Function
Setting
Description
SW 2 (Bottom 8 DIP Switches)
Switches 7 and 8
MUST
be turned
OFF
for the 9024.
OFF
ON
OFF
Input Power
Failure Mode
Reverse/Shadow
Input
Overlapping
Dual Gates
3
4
7 and 8
OFF
ON
Circuit Board
Power
Management
Not Used
6
Used for
115/230 VAC
input power. Board receives
Constant power
.
Used for
Solar
input power. Board
Minimizes power
when not in use. All terminals
shut down power except
main terminals 1, 2, 3
and
loop detector ports
.
OFF
ON
5
Switch 5
MUST
be turned
OFF
for the 9024.
DO NOT USE
for the 9024.
Overlapping gates
ARE
used (Dual swing gates ONLY).
Secondary gate starts to open a few seconds before primary gate starts.
Opening direction
using
ON
setting.
Opening direction
using
OFF
setting.
Changes direction operator will cycle open
upon initial AC power up and open command.
Reverses Gate
Stops Gate
(Slide gates)
Quick-Close
Timer Override
(Slide gates)
Exit Loop Port
Output
Full Open Input
Normal Setting.
Input to main terminal 10 and reverse loop will
reverse
gate
during
close
cycle.
Input to main terminal 10 and/or reverse loop will
stop
gate during
close
cycle –
gate will
continue to close
after input to main terminal 10 and/or reverse loop are
cleared (Helps prevent tailgating).
Setting
MUST
be used
Normal Setting.
Gate
operates normally
using ONLY battery back-up power.
After batteries are depleted, gate will remain
CLOSED
until AC power is restored.
Gate
fully opens
and operator
shuts down
until AC input power is restored.